https://www.natachi.net

AMC210NT

HỖ TRỢ
Mr.Nam
0903999832
Hotline
0969055593
Phòng KT
02838 636 919
Sales1
0935006453
Sales2
0907792659
THỐNG KÊ
  •    Đang online: 4
  • Lượt truy cập: 1346972
SẢN PHẨM
  • AMC210NT
  • Giá:
    Liên hệ
  • Xuất xứ:
  • Lượt xem:
    32769
AMC210NT Series The Aliamag AMC210NT series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES
 

 

 Three line LCD display Flow Rate / Totalizer
 Accuracy of +/-0.4% value of reading
 Bi-directional flow measurement, current and pulse output
 Large digital display
 Records up to 99 power on/off time
 MODBUS/HART communication

 

 
SPECIFICATION
 

Excitation: Keyboard:
DC pulsed 3 external keys for programming 
Display: and display control
3 lines LCD with illumination Low Flow Cutoff:
Line 1 0 to 9.9 %
11 digit totalizer for forward flow Data logger Function:
11 digit totalizer for reverse flow 99 times flowrate records for power on/off
11 digit totalizer for difference Record Data:
Line 2 Date/Time when Power on/off
5 digit flowrate / velocity / % / mA / HZ Flow rate when Power on/off
Line 3 Totalizer when Power on/off
Parameter / Query / Clr tot / Query LOG Damping:
Alarm, Guidance 0 to 99 Seconds
Unit Density Setting:
M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH 0.1 to 9.99 g/cm3
GPM, ML/H, ML/m, ML/sec Self Diagnosis:
Measuring Range: The following error message are 
Min.  0 to 0.15 m/s displayed if failure occurs
Max. 0 to 15 m/s - Coil failure
Accuracy: - Power failure
+/-0.4% read-out values (Velocity >=0.5 m/s) - Overranged output
+/-0.002 m/s (Velocity < 0.5 m/s) - Internal error
Repeatability: - Overflow
+/-0.1% read-out values - Empty pipe
Current Output: Cable Entry:
4-20 mA (Isolated) Standard :PG11 Option:1/2"NPTF
Load Protection Class:
Max. 600  IP 65
Pulse output: Ambient Temperature:
Open collector
-25 to +65 oC
Rating Material:
3 to 30 VDC, 20 mA Max.  Aluminum Alloy
Pulse Rate: Power Supply:
1)Scale pulse (Pusle/M3, Pulse/L, Other) 90-260 VAC, 50/60 Hz
2)Frequency: 0-5000 Hz 24VDC +/-10% (Option)
Pulse Width: Power Consumption:
50% of band width 3-17 W (Dependent on sensor size)
Alarm: Weight:
High/Low with open collector output 1.4 Kg
Rating Mounting:
3 to 30 VDC, 20 mA Max.  Wall mounting
Communication: Bracket on 2" pipe
RS 485 (MODBUS Protocol)  
HART signal  
Data Storage:  
Operation parameters and totalizer  
figures are stored by EEPROM for more  
than 10 years
SẢN PHẨM KHÁC
1 2 3